Broken Clasp or Major Connector
1. Take the impression with the partial in place.
2. After proper setting time, remove the impression keeping the partial in the impression.
3. Pour immediately or send it to Artisan according to material instructions.
4. If you have the clasp, send it along with the partial still in the impression.

|
|
|
Take an impression without the partial in place, send the impression or model along with the partial to Artisan.
|
|
|
|
Take an impression with the partial in place. After proper setting time, remove the impression keeping the partial in the impression. If the margins are not captured, take another impression without the partial in place, for adaptation of crowns and margins. Send both impressions to Artisan along with an opposing impression/model and a bite registration.
It is recommend that we have the partial in the laboratory for the entire time it takes to fabricate the crown. If that is not possible please contact us for alternative arrangements.
|
|
|
|
1. If occurred during seating, send crown, impression and all model work back to Artisan.
2. If occurs on existing or previously seated crown, and making a new crown is not possible, it is recommended to try using a porcelain repair kit. |
|
|
|
|
|
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
 |
 |
|
|
|
|
Artisan
Dental Laboratory
2532 SE Hawthorne
Portland, OR 97214
1-800-222-6721
(503) 238-6006
(503) 231-3684 FAX
|
|
|
|
|
|
|
 |
 |
 |
 |
 |
|
|